Rocstor
ROCFORCE

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

The Rocforce series On-line double conversion UPS with full-time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance from a UPS.  Input power factor correction, high efficiency and parallel redundant capability provide a superior level of power quality for sensitive electronic equipment and computer loads.

  • Rack Mount  or  Tower Convertible Design
  • Simple Parallel Installation
  • Full-time Digital Signal Processor Control
  • Programmable Frequency Converter
  • LCD/LED Mimic Panel
  • Smart ECO Mode
  • Simple and Easy to Use
  • Power Range and Runtime Scalability
  • Optional Galvanic Isolation Transformer
  • Optional Hot Swappable Battery

Rocforce
Parallel Redundancy On-Line UPS
Using our field proven Digital Signal Processor (DSP) with SMD techniques, the Rocforce series UPS achieves high reliability and greater immunity from utility power problems.  The front display panel provides all major systems parameters and operational status of the UPS that include full diagnostics for simple, easy servicing.  The Rocforce series UPS uses a patented inverter control technology that allows it to achieve N+1 scalable redundant power without the use of additional components.  The Rocforce parallel configuration also eliminates any single point of failure.

Simple Parallel Installation
To increase the power capacity or configuring a parallel redundant UPS system, up to 3 additional Rocforce series UPS’s are simply interconnected using the CAN-bus RJ45 cables on the rear of the Rocforce series UPS.

Programmable Frequency Converter
The Rocforce series UPS may be used as a frequency converter.  Simple programming through the front LCD panel provides the convenience of 50 or 60Hz.

Intelligent Self-Diagnostics
The Rocforce series UPS with DSP Control, no comma systematically checks each component and displays the result using the LCD display.  This feature allows service technicians the ability to pinpoint and repair the UPS very quickly. 

High Input Power Factor and Low Current THD
The Rocforce series UPS provides a ‘clean’ rectifier connection to the utility source.  It meets today’s industry standard for energy saving with low reflected harmonic pollution to the utility.  The Rocforce series 2 words UPS achieves up to 0.99 Input Power Factor as well as <6% Input Current THD.

Cold Start Function
The Rocforce series UPS may be powered up without the presence of the utility, providing AC power for immediate power requirements.

Full-time Digital Signal Processor Control
The Mars II Full Time DSP control system ensures a pure Sine-Wave on the input and the output of the UPS.  The DSP control also provides the user with simple access to the UPS systems’ operational information via the front display panel.

True Double Conversion On-line Technology
Power disturbances from the Utility are eliminated because the UPS regenerates the power to provide clean electricity 24/7.  The VFI (Voltage Frequency Independence) of the Rocforce series UPS complies with the international EN62040-3 standards. 

Dual Input Loops
The Rocforce series UPS provides single input connections as standard.  Optional input terminal connections for the bypass and rectifier are available.  A three-phase input and single phase output option is also available.

LCD/LED Mimic Panel
A precise LCD/LED display provides real time status and parameter readings.  These include AC Input and Output Voltage, Frequency, Battery Voltage, Load Level, UPS temperature, etc.  A full size, user-friendly microprocessor based LCD display, provides advanced monitoring functions and simple operation.

Energy-efficient UPS
The AC to AC efficiency of the Rocforce series UPS may be up to 90% at 25% load and higher with larger loadings in normal VFI operation.  Using the ECO mode, an efficiency of up to 97% can be achieved.

Simple and Easy To Use
The LCD front panel provides direct access to the DSP controller.  Changes to the UPS operational modes and parameters such as output voltage settings, fine adjustments for frequency, bypass voltage settings as well as alarms status may be easily performed.

Emergency Power Off
The Emergency Power Off enables users to remotely shutdown the UPS.

Smart ECO Mode
Energy Saving using ECO mode.

Matching Battery Cabinet
Add matching battery cabinets and extend the backup time up to several hours.

Power Range and Runtime Scalability
The Rocforce series UPS provides an excellent return on your investment.  The system is fully modular and allows you to increase the overall power output, battery runtime, and redundancy as your needs and requirements grow.  The modular design eliminates any single point of failure.

Optional Galvanic Isolation Transformer
The Optional Galvanic Transformer provides isolation between the input and the output of the UPS and various secondary voltage 110/115/120/208/220/230/240Vac.

Advanced Battery Discharge Management
The Rocforce series UPS automatically manages the End-Discharge voltage of the internal batteries according to the load.  The ABDM function prevents the deep discharge of the batteries during a power failure.

Silent Fan Control
The Rocforce series UPS employs variable-speed, forced air cooling fans.  These fans will vary in speed according to the percentage of load.  This variable-speed control ensures a low audible noise level making the Rocforce series UPS suitable for most environments including offices and hospitals.

Communication Capability
The Rocforce series UPS is shipped with monitoring and shutdown software.  The software allows the control and graceful shutdown when Utility Power fails

  • Remote testing of the major operating UPS functions.
  • Communicate via SNMP/WEB card.
  • Access UPS functions via the WEB.  

Optional External Battery Charger
With its isolation conversion technology plus precision control, the optional charger can be installed in
Parallel operation for up to 4 units.  The specifications are as follows:


AC Input Range

100-280Vac, 45-65Hz

Maximum Power Output

1000W, continuously

Operation Mode

Constant Voltage with Current Limitation

Maximum Parallel Units

Up to 4 units

Protections

Over-voltage, Against Output Short-Circuit & Isolated devices for Opposite Polarity Connection

Mounting

Mounted on the rear of the UPS or the wall

Dimension (WxHxD, mm/inch)

166x282x86 / 6.6x11.1x3.4

Net Weight (Kgs/lbs)

3.2 / 7.1

Variety of Customer Options Slots
The Rocforce series UPS also provides one or two additional Customer Options Communication
slot(s) in additional to the standard RS232. An internal 2nd RS232, USB, RS485, Dry Contact, or WEB/SNMP card provides isolated contacts for industrial and remote alarm applications.

Super Compact Convertible Design
The Rocforce series UPS is small and compact.  Install the UPS in a 19” rack and utilize the space efficiently.

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

Technical Specifications

ROCFORCE – RPQ 6K PMBBC TRM 5U

Consist of

Part Number

Rack Mount

Power Module 6000  

PM 6000 TRM2U

2 U

Battery Bank Cabinet

BBC20QJ07

3 U

 Technical Specifications:


Model

 ROCFORCE – RPQ 6K PMBBC TRM 5U

INPUT

 Voltage Window

160~280Vac
 

 Frequency

45 ~ 65 Hz

 Phase/Wire

Single, Line + Neutral + Ground

 Power Factor

Up to 0.99 at 100% Linear Load

 Current THD (100% linear load)

<6%

OUTPUT

 Voltage Window

200/208/220/230/240Vac Selectable

 Voltage Adjustment

Nominal +1%, +2%, +3%, -1%, -2% or -3%

 Voltage Regulation

±2%

 Capacity

6000VA / 4200W

 Rated Power Factor

0.7 Lagging

 Wave Form

Sine Wave, THD<3%(no load to full load)

 Frequency Stability

±0.2%(Free Running)

 Frequency Regulation

±1Hz; ±3Hz

 Transfer Time

0ms

 Crest Factor

3:1

 Efficiency(AC to AC, Normal)

Up to 90%

 Efficiency(AC to AC, ECO)

Up to 95%

 Autonomy

>=8 min.

 DC Start

Yes

BATTERY BANK BBC20QJ07

 Type

Sealed Lead Acid Maintenance Free 

 Capacity

12V/7AH

 Quantity

20pcs

 Voltage

240Vdc

 Recharge Time

4 hours to 90%
 

Without Batteries

18.0kg/39.7lb.

With Batteries

68.0kg/149.8lb

DISPLAY

 Status On LED + LCD

Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, and Transferring with interruption & UPS Fault. 

 Readings on LCD

Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature.

Self-Diagnostics

Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking

ALARMS

 Audible and Visual

Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions

PROTECTION

 Overload(w/simulated thermal tripping I-T Curve)

Inverter Supply: 105%~150% for 160 seconds ~ 2 cycles before switching bypass.
Bypass Supply: 105%~200% for 500 seconds ~8 cycles before stopping supply load.

 Short Circuit

Switch off Immediately

 Overheat 

 AC Mode: Switch to Bypass
Backup Mode: Switch off the UPS

 Battery Low

Alarm and Switch Off

 Noise Suppression

Complies with EN62040-2

 Spike Suppression

Complies with EN61000-4-5

Heat Dissipation
(At Full Linear Load)

< 615W
 
 

Leakage Current

< 3mA at Full Load

PHYSICAL

Dimensions
WxDxH (mm/inch)
 

 440x680x88/17.3x26.8x3.5

Input / Output Connection

Hardwire

 External Battery Connection

Plug-in & Play

 Net Weight (kgs/lbs)

24/52.9

ENVIRONMENT

 Operating Temperature

0 to 40 C/ 32 to 104 F

 Temperature Warning

The battery design life is based on a temperature of 25 C/77 F, Ambient temperature above this range will affect battery life

 Altitude

0~2000M/6600ft up to 40 C/104F, 3000M/9900ft up to 35 C/95 F

 Humidity

90% RH Maximum, Non-Condensing

 Noise

<50dB(at 1 Meter/3.3ft)

COMPUTER INTERFACE

 Interface Type

Standard RS232 Interface

 Communication Slots

2nd RS232, USB, RS485, Relay Contact, SNMP/WEB Card, etc.

SAFETY CONFORMANCE

 Quality Assurance

ISO9001 Certified

 Safety Standard

EN62040-1-1, UL1778

 EMC Standard

EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A

Marks

cUL, UL

Specifications subject to change without prior notice

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

Extended Battery Bank

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

Runtime

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

Product Images

ROCFORCE

Power Module

ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE

Transformer

ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE

Battery Bank

ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE ROCFORCE

ROCFORCE - RPQ 6K PMBBC TRM 5U

Redundancy On-Line UPS - Tower and/or Rack Mount Convertible

User Manuals